Ceramics-Silikáty 38, (3) 159 - 162 (1994)


CORROSION OF LOW-POROSITY MATERIALS PREPARED WITH THE USE OF GYPSUM-FREE PORTLAND CEMENT
 
Škvára František
 
Institute of Chemical Technology, Department of Glass and Ceramics, 166 28 Prague 6, Technická 5

The differences in the resistance to corrosion GF cement and ordinary portland cement are due to different microstructural characteristic, above all significantly lower porosity of hardened GF cement pastes and concretes. The hardened GF cement pastes and concretes are corroded by the same mechanism (corrosion of the 2nd and 3nd types) as the corresponding PC materials. The difference between GF cement and PC is based on the corrosion rate, which is much lower with the GF cement materials.


PDF (7.1 MB)
 
Licence Creative Commons © 2015 - 2024
Institute of Rock Structure and Mechanics of the CAS & University of Chemistry and Technology, Prague