Ceramics-Silikáty 32, (3) 241 - 255 (1988) |
|
MĚŘENÍ PRŮBĚHU TEPLOTY PŘI HYDRATACI ANORGANICKÝCH POJIV
MEASURING THE COURSE OF TEMPERATURE DURING HYDRATION OF INORGANIC BINDERS |
Všetečka Tomáš 1, Hazdra Pavel 2, Všetečková Mirka 3 |
1 Armabeton, technickÝ rozvoj, Antala StaŠka 32, 140 00 Praha 4
2 České vysoké učení technické, Fakulta elektrotechnická, Suchbátarova 2, 160 00 Praha 6
3 České vysoké učení technické, Stavební ústav, Šolínova 7, 166 08 Praha 6
1 Armaheton, Department of Technical Development, 140 00 Prague 4
2 Czech Technical University, Electrotechnical Faculty, 160 00 Prague 6
3 Czech Technical University, Institute of Building Construction, 166 08 Prague 6
|
Je popsáno zařízení a metodika pro sledování časového průběhu hydratační teploty pojiv. Principem je kontinuální měření teploty, která charakterizuje vývoj hydratačního tepla v procesu zpevňování anorganického pojiva. Intenzitu, rychlost a průběh tohoto procesu popisuje časová závislost teploty v integrální nebo diferenciální formě. Zařízení a metoda jsou vhodné pro určování vlivu počáteční teploty směsi, teploty okolí, druhu použitého pojiva, jeho chemického a fázového složení, použitých příměsí atd. na charakter vývoje hydratačního tepla a tím celkový průběh tuhnutí. Metodu lze použít jako základní metodu při sledování průběhu reakční teploty pojiva nebo jako doplňkovou při určování reologických parametrů, charakteru nárůstu pevnosti a dalších faktorů. Na rozdíl od dosud používaných metod umožňuje tento způsob zkoumání teplotních charakteristik v laboratorních podmínkách, ale i v praxi přímo v budovaných stavebních dílech. Předností metody je možnost přechodu z kontinuálního snímání teploty na měření diskrétních hodnot.
The authors describe an apparatus and method for measuring the time course of temperature
during hydration of inoganic binders. The method is based on scanning the temperature inside
a hydrating binding agent, thus characterizing the generation of hydration heat in the course
of setting and hardening of the binder. The intensity, rate and course of the process is described by the time dependence of temperature plotted in integral or differential form. The temperature inside the hydrating binder is scanned by a silicon planar diode. The study was concerned with proving the suitability of the connection employed (Fig. 5), that of the diode chosen as the measuring probe from the standpoint of simple evaluation, measuring technique, long-term durability as well as electrical characteristics shown in Figs. I and 2, mechanical and corrosion properties of the probes plotted in Figs. 3 and 4, and listed in Table I.
The experimental part of the study dealt with practical measurements of the course of hydration
temperature made on pastes of ground Stramberk clinker. A survey of the pastes is given in Table II. The measurements were carried out under isothermal and semiadiabatic conditions. The
measuring results, i.e. the curves of the time course of temperature during hydration T = f(t)
and those of the hydration kinetics dT/dt = g(t) for the individual specimes are plotted in Figs. 6 through 13.
The advantages of the method are assessed in the conclusion. It is said to be applicable in laboratory as well as in the field. The apparatus is easy to construct, consisting of readily available parts and components. Measurements can also be carried out on inaccessible parts of building structures. The method can be employed in determing the temperature gradients in structures exposed to thermal shocks, provides information on the effect of admixtures and agents on the course of hydration, allows the quality of cement to be checked with respect to storage ageing, and the course of steam curing in the manufacture of prefabricated concrete elements to be optimized with respect to energy consumption.
|
PDF (1.4 MB) |
|
|