Ceramics-Silikáty 50, (2) 73 - 77 (2006) |
|
CORROSION OF E-GLASS FIBERS - SECURITY FACTOR OF NUCLEAR POWER PLANTS |
Mišíková Lucia, Galusková Dagmar |
Vitrum Laugaricio - Joint Glass Center of IIC SAS, TnU AD and RONA a.s.
Študentská 2, 911 50 Trenčín, Slovak Republic
|
Keywords: E-glass fibers, Corrosion, Flow-through leaching tests |
The flow-through leaching experiments have been conducted at two buffered pH values (8.5 and 10.0) of borate leaching solutions
and at two temperatures (70°C and 90°C) on the EUTAL glass fibers, used as an insulation in nuclear power plants.
Time dependencies of the total amount of leached elements Si, Al and Ca in corrosive solution have been determined. From
the leaching rates in stationary conditions the values of activation energies, Ea, have been calculated. Lower Ea values were
found for leaching at higher pH value. Higher Ea values were found for atoms so called network-forming oxides (Si, Al). Surface
of corroded fibers was analyzed by scanning electron microscopy with energy dispersive X-ray analysis (SEM/EDX).
Formation of relatively smooth continuous surface layer of corrosion products was detected at higher pH value. |
PDF (0.5 MB) |
|